Standard Models - Pesticide and Agri-Chemical Storage Lockers & Buildings  | Fire-Rated Construction | | Industry's 1st and Only FM Approved Fire Rated Wall & Roof Design Tested at Intertek Testing Laboratories
|
Securall Pesticide and Chemical Storage Lockers & Buildings are designed to ensure safe storage of your Turf Management Chemicals. All models are FM approved and meets EPA and OSHA standards for Hazardous Chemical Storage. Perfect for Golf Courses, Landscape Contractors, and Greenhouses. All standard models include interior and exterior lighting, galvanized steel shelving, and fiberglass insulation. Many optional accessories are also available. | Securall is proud to provide the highest quality safety storage products on the market today. All of our Pesticide Storage Buildings & Lockers are constructed of corrosion-resistant, galvannealed steel and are finished in 2 coats of urethane for a building that will look great for years to come. Our larger and most popular chemical storage buildings (the AG1600 and larger) are constructed of 12 gauge galvannealed steel. All models feature interlocking wall design and all-welded construction. Many models are in stock for immediate delivery. Please contact us today for more information. OPTIONAL ACCESSORIES FOR BUILDINGS | |
AG Building Image | Model No. | Test Lab Approvals | Shelving (Linear Feet) | Capacity (Cubic Feet) | Ext. Dimensions (H x W x D) | Approx. Ship Wt. (Lbs.) | | | AG200 | FM*+ | 8 | 68 | 7'1" x 5' x 3'6" | 1,431 |
| | OPFR2-200 | AG200 with 2 Hour Fire Rating Upgrade | 2,729 |
| | OPFR4-200 | AG200 with 4 Hour Fire Rating Upgrade | 3,153 |
| | AG400 | FM*+ | 20 | 145 | 7'1" x 5' x 5' | 1,898 |
| | OPFR2-400 | AG400 with 2 Hour Fire Rating Upgrade | 3,261 |
| | OPFR4-400 | AG400 with 4 Hour Fire Rating Upgrade | 3,776 |
| | AG600 | FM*+ | 36 | 211 | 8'6" x 7' x 5' | 2,236 |
| | OPFR2-600 | AG600 with 2 Hour Fire Rating Upgrade | 4,475 |
| | OPFR4-600 | AG600 with 4 Hour Fire Rating Upgrade | 5,209 |
| | AG900 | FM*+ | 48 | 308 | 8'6" x 7' x 7' | 2,742 |
| | OPFR2-900 | AG900 with 2 Hour Fire Rating Upgrade | 5,454 |
| | OPFR4-900 | AG900 with 4 Hour Fire Rating Upgrade | 6,346 |
| | AG1200 | FM*+ | 60 | 405 | 8'6" x 7' x 9' | 3,375 |
| | OPFR2-1200 | AG1200 with 2 Hour Fire Rating Upgrade | 6,434 |
| | OPFR4-1200 | AG1200 with 4 Hour Fire Rating Upgrade | 7,483 |
| | AG1600 | FM*+ | 60 | 524 | 8'6" x 10' x 8' | 5,715 |
| | OPFR2-1600 | AG1600 with 2 Hour Fire Rating Upgrade | 8,408 |
| | OPFR4-1600 | AG1600 with 4 Hour Fire Rating Upgrade | 9,584 |
| | AG2400 | FM*+ | 72 | 748 | 8'6" x 14' x 8' | 7,194 |
| | OPFR2-2400 | AG2400 with 2 Hour Fire Rating Upgrade | 10,794 |
| | OPFR4-2400 | AG2400 with 4 Hour Fire Rating Upgrade | 12,301 |
| | AG3200 | FM*+ | 84 | 971 | 8'6" x 18' x 8' | 8,852 |
| | OPFR2-3200 | AG3200 with 2 Hour Fire Rating Upgrade | 13,208 |
| | OPFR4-3200 | AG3200 with 4 Hour Fire Rating Upgrade | 15,046 |
| | AG4800 | FM*+ | 108 | 1418 | 8'6" x 26' x 8' | 10,188 |
| | OPFR2-4800 | AG4800 with 2 Hour Fire Rating Upgrade | 18,011 |
| | OPFR4-4800 | AG4800 with 4 Hour Fire Rating Upgrade | 20,510 |
| Image Coming Soon
| AG6400 | FM*+ | 132 | 1866 | 8'6" x 34' x 8' | 13,076 |
| | OPFR2-6400 | AG6400 with 2 Hour Fire Rating Upgrade | 22,692 |
| | OPFR4-6400 | AG6400 with 4 Hour Fire Rating Upgrade | 25,853 |
| | AG8000 | FM*+ | 156 | 2313 | 8'6" x 42' x 8' | 15,619 |
| | OPFR2-8000 | AG8000 with 2 Hour Fire Rating Upgrade | 27,356 |
| | OPFR4-8000 | AG8000 with 4 Hour Fire Rating Upgrade | 31,156 |
| *Complies with OSHA regulations. FM-Factory Mutual Approved. +All Hazmat Buildings are designed in accordance with specifications set forth by the National Fire Protection Association. *Please Note: Some building photos may show optional accessories.
|
|
| Standard Features(Pesticide and Agri-Chemical Storage Buildings) | Models AG Buildings |
Securall® Chemical Storage Buildings are designed with a wide variety of standard features to help our customers gain compliance with hazmat storage codes quickly and easily. Pesticide Storage Buildings are designed for outdoor storage of hazardous agricultural and turf-management chemicals. Securall's quality cannot be beat with standard features such as corrosion-resistant, galvannealed steel construction, tornado and hurricane resistant walls, and interlocking wall panels designed for superior strength and durability. All models are FM approved, include UL listed electrical accessories, and are EPA and OSHA compliant. Design Features |
| - R-11 Fiberglass insulation in ceiling and walls
- Commercial grade lockset
- Vapor Resistant Exterior Light with Photocell
- GFCI Duplex receptacle with weatherproof cover
- Steel shelving (3 Tiers) with raised edges
- Chemical/corrosive/ultraviolet resistant paint
- Leak-tight continuously welded sump
- Heavy gauge aluminum threshold
- Warning labels
- Safety posters
- Dust Proof/Fluorescent Interior Light with Weatherproof Switch
| Forklift channels with anchoring brackets Natural convection air vents Removable Galvanized Steel Safety Flooring Reflective warning tape marking entryway

|
Pesticide and Agri-Chemical Storage Buildings
 Exclusively Securall® Tornado Resistant Walls SECURALL Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart below demonstrates the wind speed that a particular length of wall will resist. 
Interlocking Wall Structure  Securall Chemical Storage Buildings are designed using interlocking wall sections which provide superior strength and durability.Exterior Wall Construction SECURALL AG Buildings are all-welded using 12 gauge (AG1600X-AG8000X Models) and 16 gauge (AG200X-AG1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.. Fire Rating - FM Approved Fire Rated Wall & Roof Design Tested at Intertek Testing Laboratory (Check with your local authority having jurisdiction for correct wall/roof rating needed) 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and 1 layer of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and 2 layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link. Safety Floor Planking Slip resistant planking 13" wide, 12 gauge galvanized steel with raised perforated buttons and debossed holes protruding down. Galvanized steel floor planking above sump area for maximum corrosion resistance. Floor planking designed to sustain a minimum uniformly distributed load of 250 pounds per square foot. Floor planking and supports are removable to facilitate sump cleaning in the event of a spill.
Door Style Door for AG200-AG400 Provide one (42" wide x 62.5”) and AG600-AG1200 Provide one (42” wide x 80”) high door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The door shall serve as personnel entrance and exit. Door for AG1600-AG8000 Provide one 60” wide x 80” high double door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The double door shall have one active leaf to serve as personnel entrance and exit. The active leaf must be equipped with a door closer. Available on B600-B1200 upgrade.
Explosion Relief Panels Used in the construction of buildings designed to store Class IA and Class IB flammables. Explosion relief panels limit the damage within an enclosed hazardous location. When the panel(s) are subjected to an explosive force, the pressure relieving panel quickly vents the force before it causes major damage. The panels are designed to release at 20 psf. Fire-Rated Buildings

Securall® Fire-Rated Storage Buildings (8'6"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall® Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents. |
|
|